Dell R820 Computer Hardware User Manual


 
Error Code Message Information
Details An error was reported during a SD card read or write.
Action Reseat the flash media. If the problem persists, see Getting Help.
RFM1014
Message Removable Flash Media <
name
> is write protected.
LCD Message Removable Flash Media <
name
> is write protected. Check SD Card.
Details The card is write-protected by the physical latch on the SD card. A
write-protected card cannot be used.
Action If unintended, remove the media and disable write protection.
RFM1201
Message Internal Dual SD Module redundancy is lost.
LCD Message Internal Dual SD Module redundancy is lost. Check SD Card.
Details Either one or both the SD cards are not functioning properly.
Action See Getting Help.
RFM2001
Message Internal Dual SD Module <
name
> is absent.
LCD Message Internal Dual SD Module <
name
> is absent. Check SD Card.
Details The SD card module is not detected or not installed.
Action If unintended, reinstall the SD module.
RFM2002
Message Internal Dual SD Module <
name
> is offline.
Details The SD card module is installed but may be improperly installed or
configured incorrectly.
Action Reinstall the SD module.
RFM2004
Message Failure detected on Internal Dual SD Module <
name
>.
LCD Message Internal Dual SD Module <
name
> failed. Check SD Card.
Details The SD card module is installed but improperly configured or failed to
initialize.
Action Reinstall the SD module and remove and reinstall SD cards.
RFM2006
Message Internal Dual SD Module <
name
> is write protected.
Details The module is write-protected. Changes may not be written to the
media.
Action If unintended, remove the media and disable write protection.
138