Denso BHT-100B Scanner User Manual


 
146
5.6 RS-232C Interface Specifications
[ 1 ] Interface Connector and Pin Assignment
The CU-7000 has an RS-232C interface port (Dsub-25S).
RS-232C interface port (Dsub-25S) on the CU-7000
Pin No. Signal Functions Signal Input/Output
CU-7000 External device
1FGFrame ground
2SDSend data
3RDReceive data
4RSRequest to send
5CSReady to send
6DRData set ready
7SGSignal ground
8CDCarrier detect
20 ER Data terminal equipment ready
The input/output voltage threshold for the logical valued signal is listed below.
Logical Value Input Voltage Threshold Output Voltage Threshold
0 3V min. 5V min.
1 -3V max. -5V max.
25
13
14
1