Eaton Electrical 9130 Power Supply User Manual


 
INSTALLATION
Eaton
®
9130 UPS (700–3000 VA) User's Guide S 164201718 Rev 2 www.powerware.com
29
7. Replace the EBM front cover.
To replace the cover, verify that the EBM cables are routed through
the EBM cover knockouts, then slide the cover from the left to the
right until it connects with the cover hook near the left side of the
EBM cabinet. Reinstall the two screws on the right side of the front
cover. For reference, see Figure 12 on page 27.
Repeat for each additional EBM.
8. Verify that all wiring connecting the UPS and EBM(s) is installed
behind the front covers and is inaccessible to users.
9. Return to Step 4 on page 25 to continue the UPS installation.
 Tower Installation
The Eaton 9130 tower cabinet comes fully assembled and ready to
connect.
C A U T I O N
The cabinet is heavy (see page 78). Removing the cabinet from its carton requires a
minimum of two people.
To install the cabinet:
1. Place the UPS on a flat, stable surface in its final location.
2. If installing additional cabinets, place them next to the UPS in their
final location.
3. Continue to the following section, “Tower Wiring Installation.”