Emerson ATCA-7350 Computer Hardware User Manual


 
ATCA-7350 Control via IPMI Programmer’s Reference (6806800H29E)
SOL Module Configuration Enable SOL Load
54
"90" is the IPMB address of the blade.
2. Set the subnet mask of the two channels.
Use the command Set LAN Configuration Parameters of IPMI2.0 with Parameter
selector of 6.
The value of Parameter selector is 6.
See table 23-4 in section 23.2 of the IPMI 2.0 specification.
For example, on Emerson shelf manager, set the subnet masks of both channel 1
and channel 2 to 255.255.0.0.
ipmicmd -k "0 90 0 0c 01 01 06 ff ff 00 00" smi 0
ipmicmd -k "0 90 0 0c 01 02 06 ff ff 00 00" smi 0
"90" is the IPMB address of the blade.
3. Set the user name.
Use the command Set User Name of IPMI2.0.
See table 23-32 in section 23.28 of the IPMI 2.0 specification.
For example, on Emerson shelf manager, set the user name to solusername.
ipmicmd -k "0 90 0 06 45 02 73 6f 6c 75 73 65 72 6e 61 6d 65" smi 0
4. Set the password.
Use the command Set User Password of IPMI2.0.
See table 23-34 in section 23.30 of the IPMI 2.0 specification.
For example, on Emerson shelf manager, set the password to soluserpassword.
ipmicmd -k "0 90 0 06 47 82 02 73 6f 6c 75 73 65 72 70 61 73 73 77 6f 72 64" smi 0
5. Set the user right.
Use the command Set User Access Command of IPMI2.0.
For example, on Emerson shelf manager, set the right of user 2 to Administrator (4).
ipmicmd -k "0 90 0 06 43 f1 02 04 00" smi 0
6. Enable the user.
Use the command Set User Password Command of IPMI2.0.
For example, on Emerson shelf manager, enable user 2.
ipmicmd -k "0 90 0 06 47 82 01" smi 0
4.3 Enable SOL Load
Use the command Set SOL Configuration Parameters of IPMI2.0. The value of Parameter
selector is 1.
See table 26-3 in section 26.2 of the IPMI 2.0 specification.
The IP addresses of the two channels cannot be set to be in the same network
segment. Otherwise, the settings fail.