2.1.2 Thermal Requirements
Shock 20G peak (half sine)
11ms
Altitude -60 to 4000 m ASL
Table 2-1 Environmental Requirements (continued)
Requirement Operating Non-operating
Table 2-2 Critical Temperature Spots
Item Thermal Dissipation Power (W) Maximum Allowable Temperature (
0
C)
CPU D510 <= 13W
D410 <= 10W
100 (Tj)
ICH8-M 3W 92 (Tc)
System Overheating
Cooling Vents
Improper cooling can lead to system damage and can void the manufacturer's warranty. To
ensure proper cooling and undisturbed airflow through the system do not obstruct the
ventilation openings of the system. Make sure that the fresh air supply is not mixed with hot
exhaust from other devices.