Enterasys Networks ELS10-27TX Switch User Manual


 
3-1
CHAPTER 3
CONFIGURING VLANS USING SNMP
3.1 OVERVIEW
This chapter describes how to create, delete or modify VLANs on the
SmartSTACK Ethernet ELS10-27TX using SNMP. This chapter describes the
procedure for using the following VLAN Configuration MIBs:
The Config Table
The Config Egress List
802.1Q Mode
The Filter GVRP table
The Static MAC table
This chapter should be used in conjunction with Chapter 4, VLAN MIB Objects,
in this manual.
3.2 THE CONFIG TABLE
The SmartSTACK Ethernet ELS10-27TX is capable of supporting 32 VLANs.
The index into the VLAN table is from 0 to 31. The present table entries can be
read, but not written, by setting the index to a value of 0 - 31. When configuring
an entry, several values are used. These values are the VLAN ID, the ports on the
VLAN, an IP address, an IP mask, and a VLAN name.
If the index is between 0 and 31, and one of these variables is read, the presently
configured table entry will be returned.
To create, modify, or delete a VLAN entry, a multiple step process is required.
The local variables must first be set with the values desired, followed by a
command to process the variables. For a list of configuration MIBs, refer to
Chapter 3, VLAN MIB Objects.