Connecting to COM Port for Local Management
3-22 Installation
Connecting to a VT Series Terminal
ToconnectaVTSeriesterminaltoanEnterasys NetworksDFEmoduleCOMport
(Figure 3‐10),useaUTPstraight‐throughcablewithRJ45connectorsandanRJ45‐to‐DB25
femaleadapter,andproceedasfollows:
1. ConnecttheRJ45connectoratoneendoftheUTPstraight‐throughcabletothe
COM
portontheEnterasys Networksmodule.
2. PlugtheRJ45connectorattheotherendoftheUTPstraight‐throughcableintothe
RJ45‐to‐DB25femaleadapter.
3. ConnecttheRJ45‐to‐DB25adaptertotheportlabeledCOMMontheVTterminal.
4. TurnontheterminaltoaccesstheSetupDirectoryand
setthefollowingparameters:
Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFE‐GoldSeriesConfigurationGuideforfurtherinformation.
Figure 3-10 Connecting a VT Series Terminal
Parameter Setting
Mode 7 Bit Control
Transmit Transmit=9600
Bits Parity 8 Bits, No Parity
Stop Bit 1 Stop Bit
1 UTP straight-through
cable with RJ45 connectors 3 RJ45-to-DB25 VT adapter
2 RJ45 COM port 4 VT series terminal
 ÀÃ
CPU
POE
1X
G
R
O
U
P
1
OFFLINE/
RESET
COM
MGMT
GROUP
SELECT
GROUP
1
2
3
4
5
6
1
2
3
4
4G4285-49
Gb ENET
Á