Epson 9840 Computer Monitor User Manual


 
INTERFACE MODEL 9840 VER 6.0.2
These are the units for Velocity:
00 – I/M 01 – C/M
Front Panel Display Command (F)
This command is used to set the front panel display of the Model 9840 to a desired
combination of item and unit. There are five subcommands: Front panel View (FV), Front
panel Set (FS), Front panel Alternate(FA), Front panel pointer control to line 1 (F1), and
Front panel pointer control to line 2 (F2) .
Front Panel View Command (FV)
The Front panel View (FV) command just tells you what is currently on the display, and
what will be displayed when the View button on the front panel is pressed.
Example:
@123FV
Acknowledge:
@123 Active Display shows Load A in Lb
Other Display shows Peak A in Lb
Front Panel Set Command (FS)
The Front panel Set (FS) command allows you to specify the item number and unit
number for what is currently on the front panel display. The format is FS (item
number)(unit number), where the first item and unit numbers are 2 digits each and may
be found using the question mark command (?).
Example:
@123FS0200
Acknowledge:
@123 Active Display shows Vall A in Lb
Other Display shows Peak A in Lb
Front Panel Alternate Command (FA)
The Front panel Alternate (FA) command allows you to switch between the currently
displayed item and unit and the alternate item and unit just as if you had pressed the
View button.
Example:
@123FA
Acknowledge:
@123 Active Display shows Peak A in Lb
Other Display shows Vall A in Lb
Front Panel Pointer Control to Line 1 (F1)
The Front Panel Pointer Control to Line 1 (F1) assigns the view pointer control to
display line 1 (upper line of the display) and shows what is on the display. This
allows the operator to know which line will be configured or accessed.
Example:
MODEL 9840 PG 27 PUB. 2856-16