Epson C I - 4 0 4 0 Printer User Manual


 
Configuring the printer
3-16
S PROTOCOL (Only indicated if the serial interface is selected)
Selectable are: DTR, XON/XOFF, or XON/XOFF + DTR.
S CTS MODUS (CI - 4040, only indicated if the serial interface is selected)
The input signal CTS (Clear To Send) of the RS232-C interface can be set
to ignore. The printer will send immediately data to the system.
S Sub-Function ADJUSTMENT
S AGC Position
AGC (Automatic Gap Control) is an integral part of the paper handling
capabilities of the printer. It is an automatic adjustment function which
ensures an optimal print quality when using various paper thicknesses.
The gap adjustment will automatically take place whenever paper is
inserted
S after the paper source has been changed
S from park position (fanfold)
S after Power On
S after the printer has been in the STOP mode
S an AGC command has been issued.
The reference point for the measurement of the paper thickness is the
AGC Position of the first print line. Default for the horizontal AGC Position
is 24 (= ink ribbon exchange position), any position from 4 to 131 (at 10
cpi) can be selected.
An adjustment of the AGC Position is only necessary if a measurement at
the default position does not reflect the paper thickness of the area to be
printed on or if there is a paper edge (e.g. of a label) in that position (the
measuring process requires a plain paper-surface).
In addition to the automatic AGC function, random measurements of the
paper thickness can be invoked by the AGC command, or a specific platen
gap can be set using the PCC command. This is to meet the requirements
of forms with complex properties. For details see the Programmers Manual
for the printer.