Epson EMP-800UG Projector User Manual


 
70
Main menu Sub-menu Function
Default
setting
Setting P in P Sets the input source for the sub-screen of the Picture
in Picture function to either Composite Video or
S-Video.
• The Picture in Picture function can be used by
pressing the [P in P] button. (P.60)
Composite
No-Signal
Msg.
Sets the message status and background color at times
such as when no video signal is being input.
• To change the user's logo, you need to record and set
your own logo. (P.98)
Blue
Prompt Sets whether the source prompt for the input image is
displayed on the screen or not.
ON
A/V Mute Sets the screen status when the [A/V Mute] button is
pressed.
• To change the user's logo, you need to record and set
your own logo.
Black
Comp1 Input Sets the video signal for Computer 1 input. Digital-RGB/
Analog-RGB
Comp2/
YCbCr Input
Sets the video signal for Computer 2 input. Analog-RGB
Sleep Mode Sets the energy saving operation when no video signal
is being input.
• When set to
ON
, projection stops automatically and
the projector changes to sleep mode if no operations
are carried out for 30 minutes while the "No-Signal."
message is being displayed. (The operation indicator
lights orange.)
• Projection starts again when the [Power] button is
pressed.
ON
Reset Returns the adjustment values for the Setting menu to
their default settings.
• Press the button to display the confirmation
screen, and select Ye s .
•Select Reset All to return all menu settings to their
default settings.
-
Using the Projector Menu Functions