Power Supply
Option slot power limits
Maximum Current
+5 Volts
+12 volts
-5 Volts and -12 Volts
For each slot
7 Amps 1.5 Amps
0.3 Amps
For all four slots 16 Amps
3 Amps
0.3 Amps
Environmental Requirements
Condition
Operating range Non-operating
range
Storage range
Temperature
41° t0 90° F
-4°to140°F
-4° to 140° F
(5° to 32° C)
(-20° to 60° C)
(-20° to 60° C)
Humidity
20% to 90%
10% to 90%
10% to 90%
(non-
condensing)
Altitude -330 to 9,900 ft
-330 to 39,600 ft
-330 to 39,600 ft
(-100 to 3,000 m)
(-100 to 12,000 m)
(-100 to 12,000 m)
Maximum
wet bulb
Acoustical
noise
68° F
(20° C)
37.5 dB(A)
104°F
134° F
(40° C) (57° C)
N/A
N/A
A-4 Specifications