Epson C3000 Printer User Manual


 
194 Maintenance and Transportation
R4CE640
long.bk Rev. E
A5 size MAINT.FM
6/10/04
L
Proof Sign-off:
ABE J.Hashimoto, K.Iwamura
M.Ishigami
S. Halvorson
w
Warning:
The fuser unit can be very hot if the printer has been in use.
Turn the printer off and wait for 30 minutes until the
temperature has subsided before replacing the fuser unit.
Do not dispose of the used fuser unit in fire, as it may explode
and cause injury. Dispose of it according to local regulations.
Keep the fuser unit out of the reach of children.
Replacing the fuser unit
Follow these steps to replace the fuser unit.
1. Turn off the printer, and wait for 30 minutes until the
temperature has subsided.
2. Press the latch on cover B and open the cover.