Epson C3000 Printer User Manual


 
Troubleshooting 257
R4CE640
long.bk Rev. E
A5 size TROUB.FM
6/10/04
R
Proof Sign-off:
ABE J.Hashimoto, K.Iwamura
M.Ishigami
S. Halvorson
9
9
9
9
9
9
9
9
9
9
9
9
Install Fuser
There is no fuser unit installed or the fuser unit is not installed
properly. Turn off the printer and install the fuser unit if it is not
installed.
If a fuser unit is already installed, turn the printer off and reinstall
the unit after it has cooled off (30 minutes). Then open cover B
and D. Remove the fuser unit, then reinstall it properly. Close
covers D and B. The error clears automatically if the fuser unit is
properly installed.
If the error is not cleared, the fuser unit is out of order. Replace it
with a new fuser unit.
Install LC1
The paper tray of the standard paper cassette is not installed, or
not installed properly. Install the paper cassette correctly to clear
this error.
Install LC2
The paper trays of the optional paper cassette unit are not
installed, or not installed properly. Install the paper trays
correctly to clear this error.
Install Photoconductor
There is no photoconductor unit installed or the photoconductor
unit is not installed properly. Turn off the printer and install the
photoconductor unit if it is not installed.
If a photoconductor unit is already installed, confirm cover D is
closed. Otherwise, turn off the printer, open cover A, and then
open cover D. Remove the photoconductor unit, then reinstall it
properly. Close covers D and A. The error clears automatically if
the photoconductor unit is properly installed.