1-5
1-4 System Composition
The following illustration shows the system composition of @E.Terminal for MC.
@E.Terminal for MC
Screen editor
"V-SFT-5"
(V5.3.0.0 or later)
SX bus
Ethernet/RS-232C or RS-485
LAN/CN1/MJ1/MJ2
USB-B
MJ1/MJ2
External PG
(only No. 1 axis)
[No. 1 axis]
SX bus station No.: "201"
[No. 2 axis]
SX bus station No.: "202"
[No. 8 axis]
SX bus station No.: "208"
FALDIC ALPHA5
FALDIC - α
FALDIC ALPHA5
FALDIC - α
FALDIC ALPHA5
FALDIC - α
"V-CP"
Up to 8 servos and I/O terminals each
can be connected.
SX bus station No.: "221"
SX bus station No.: "228"
I/O terminal
Input 8 points/
Output 8 points
(NR1SW-16T65DT)
I/O terminal
Input 8 points/
Output 8 points
(NR1SW-16T65DT)
Starting up signal etc.
RDY etc.
Programming support tool
SX-Programmer Standard
"NP4H-SWN" (V2.3.5.1 or later)
SX-Programmer Expert (D300win)
"NP4H-SEDBV3" (V3.4.4.0 or later)
"NW0H-CNV + NW0H-CA3"
or
commercially available USB cable
PLC/general purpose
computer
Note) Connectable servo amplifier
FALDIC-α (RYS***S3-VSS, RYS***M3-VSK)
FALDIC ALPHA5 (RYT*** 5-VS )