Maintaining the Projector 157
Follow these steps to replace the lamp and air filter:
1. Turn off the projector and unplug the power cord.
2. Let the projector cool for at least an hour (if it has been on). The
lamp is extremely hot immediately after use.
3. Loosen the lamp cover screw (you don’t need to remove it). Then
slide the lamp cover to the side and lift it off of the projector.
4. Loosen the two screws holding the lamp in place (you can’t
remove them).
warning
Let the lamp cool fully
before replacing it.
In the unlikely event that
the lamp has broken, small
glass fragments may be
present and should be
removed carefully to avoid
injury.
If the lamp is used after the
replacement period has
passed, the possibility that
the lamp may break
increases. When a lamp
replacement message
appears, replace the lamp
with a new one as soon as
possible, even if it is still
working.
Loosen, but don’t
remove these screws