Pressure Systems 9046 Scanner User Manual


 
Pressure Systems, Inc. Model 9046 User’s Manual
Page 34 www.PressureSystems.com
5.3 Reset (Command ’B’)
Purpose: Instructs the module to reset internal operating parameters, and to set all internal
control variables to their default "reset" state (see description below). The current TCP/IP socket
connection will remain open. Execution after a power off/on cycle is optional (unnecessary).
Command "B"
’B’ is the operation code.
Response "A" or "Nxx"
’A’ for acknowledge; ’N’ for negative acknowledge,
error code xx.
Description: The module returns to the following "reset" states if this command is executed:
The Offset calibration adjustment coefficient for each transducer is set to the last value
stored in flash memory.
The Gain calibration adjustment coefficient for each transducer is set to the last value
stored in flash memory.
Number of Samples for Data Averaging is set to last value stored in flash memory
(factory default = 64).
Any autonomous host data delivery streams defined by ’c’ sub-commands are reset
(undefined).
Example:
Command module to reset "power-up" defaults:
"
B"
Read following response:
"
A"
Note
NUSS does not use this command normally. You may execute it
manually via the ’Execute Commands’ or ’Execute Script’ functions
of NUSS - though this should be avoided if NUSS is currently
operating the module via other NUSS functions.