Pressure Systems 98RK-1 Scanner User Manual


 
Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual©
Page 81 www.PressureSystems.com
06
IP Address Resolution Method, as hex state:
0000 = Use Static IP Address stored in module’s non-volatile memory
0001 = Get Dynamic IP Address from external RARP/BOOTP server
13
07
TCP Back-Off Delay, as hex value (or FFFF). FFFF means use low-order
byte of module’s Ethernet Address as value instead. In either case, back-off
delay in microseconds is calculated from decimal equivalent of hex value:
delay = decvalue * 20
14
08
TCP/IP Data Field Size Prefix (with 2-byte big-endian binary value),
as hex state: 0000 = None (default)
0001 = Yes
16
09 TCP Connect Port, as hex value (e.g. 2328 = 9000 decimal, default). 17
0A
Auto UDP Broadcast@Reset, as hex state:
0000 = No (default)
0001 = Yes
18
0B
Position of 4-state Internal Calibration Valves (C1/C2, C3/C4), as hex state:
0000 = RUN position (C2/C4 Energized, C1/C3 Not)
0001 = CAL/RE-ZERO position (C1/C4 Energized, C2/C3 Not)
0010 = LEAK/CHARGE position (C2/C3 Energized, C1/C4 Not)
0011 = PURGE position (C1/C3 Energized, C2/C4 Not)
(see end-of-table NOTE +) (see also Chart at end of 'w' command)
12/0C
00/00
00/01
01/00
01/01
0C
Temperature Status of Each Scanner Transducer, as 16-bit hex bit map,
each bit representing the current status of a transducer/channel (16-1)). Bit
values are:
0= transducer operating within the specified operational limits.
1= transducer operating outside the specified limits.
(see end-of-table NOTE +)
0D
Minimum Temperature Alarm Set Point (in degrees C), as decimal (**)
format 0 representation of internal IEEE float, with leading space).
19
0E
Maximum Temperature Alarm Set Point (in degrees C), as decimal (**)
format 0 representation of internal IEEE float, with leading space).
19
0F
Cluster (C), Rack (R), and Slot (S) Address, each item encoded as a hex
digit (most significant digit always zero): 0CRS
(see end-of-table NOTE ++)
10 External DH Scan Interval (in seconds) as decimal (**) integer value. 1A
11 Thermal Update Scan Interval (in seconds) as decimal (**) integer value. 1B
(+)NOTE: These 4-byte hex status fields may also be returned in autonomous data
streams, but as pure binary extensions of each stream packet’s binary
header (see ‘c’ command, ii=05, bbbb=0002).
(++)NOTE: The 98RK-1 Scanner Interface Rack can operate as a single unit with up to
eight Model 9816 pressure scanners installed in slots of each rack. Racks
may also be grouped together in clusters of racks as part of a larger data
acquisition system installation. In order to physically identify individual