Extron electronic 305SA Switch User Manual


 
COMPUTER IN
AUDIO
IN OUT
MONITOR OUT
IR OUT
S G
Audio and Video
Output Port (at rear)
PVT CV D
AUDIO IN
L
R
VIDEO IN
IR OUT
S G
Decora
Faceplate
Mounting
Screws (2)
IR Output
IR Input
Connector
(at rear)
IR Input
Connector
(at rear)
Line Out
Audio
Connector
(at rear)
Audio and Video
Output Ports (2** at rear)
** Each RGB Wallplate needs
2 Output Cables, A and B.
Audio and
Video input
Connectors
RJ-45 LAN Pass-through
Connectors (2 at rear)
CAT5e
CAT5e
GS
GRL
RGB A
OUT
RGB B
OUT
PVT RGB D IP Plus
IR Output
Audio and
Video input
Connectors
Line Out Audio
Output Port
Local Monitor
Output Port
CAT5e
CAT5e
RJ-45 LAN
Pass-through
Input
Connectors
FRONT REAR
REAR
FRONT
123
4
ON
5
5-pole EDID
DIP switch
(at rear)
EDID Learn
Button
EDID Learn
Status LED
Stage 2:
Mounting the PVT
Wallplates and the
MediaLink Controller
Stage 2 Involves Installing and Cabling the Devices Shown Below.
NOTE: The installation must conform to national and local electrical codes and UL requirements. See the
device user guide for details.
PVT CV D and PVT RGB D IP Plus AV Source Input Wallplates
• Where it goes: Installs in a wall near input source location.
• What it does: Transmits an input source’s composite or RGB
video signal and audio signals to the switcher.
In addition the PVT RGB D IP Plus allows pass-through Ethernet
connection.
NOTES:
• The PVT CV D is a 1-gang wallplate.
• The PVT RGB D IP Plus is a 2-gang wallplate.
• Both the PVT RGB D IP Plus and the optional
PVT RGB D (EDID) incorporate EDID Minder. This allows
the transmitter to communicate the appropriate EDID
information to the source, ensuring correct video output
resolution.
Before fully installing the PVT RGB D IP Plus wallplate,
see EDID MInder on page 42 for setup and operating
details.
PoleVault IP Systems • Installation — Stage 2 (Wallplates and MLC) 21