EDID Minder
The PVT RGB D IP Plus (EDID) and the PVT RGB D (EDID) incorporates EDID Minder, which
allows the transmitter to communicate the appropriate EDID information to the source, ensuring
correct video output resolution.
The 5-pole EDID Minder settings DIP switch is located on the rear of the wallplate.
Once installed, these switch settings are only accessible by removing the device from its
installed location.
The factory EDID setting (default) is 1024x768@60 Hz (preset 2).
The EDID Minder has two modes; a Preset (Emulation) mode and a Learn mode.
• Preset Mode is available on all PVT RGB (EDID) models, and allows selection of
pre-programed EDID rates, as shown in the table below.
• Learn Mode is available only on the PVT RGB D Plus model, and enables the
displays specific EDID information to be recorded and emulated by the input wallplate.
To use the EDID Minder mode in Preset or Learn Mode, follow the instructions below
Using Preset Mode
1. If already installed, disconnect any sources and displays from the front panel and remove
the wallplate from the wall.
2. On the rear panel, set DIP switch 1 to 50 or 60 kHz as desired.
3. Set DIP switches 2 through 5 accordingly to match the desired EDID rate
(see the table below).
4. Connect the video source to the Computer In VGA connector
and a local display device to the Monitor Out port.
5. Restart the video source and display devices. Verify the image, making
any changes to the EDID settings as needed.
6. When the image is correct, re-install the wallplate.
Preset
Number
Switch setting
Resolution
2 3 4 5
0 OFF OFF OFF OFF Learn Mode (PVT RGB D Plus only)
1 OFF OFF OFF ON 800x600
2 OFF OFF ON OFF 1024x768 (default)
3 OFF OFF ON ON 1280x720
4 OFF ON OFF OFF 1280x768
5 OFF ON OFF ON 1280x800
6 OFF ON ON OFF 1280x1024
7 OFF ON ON ON 1360x768
8 ON OFF OFF OFF 1366x768
9 ON OFF OFF ON 1400x1050
A ON OFF ON OFF 1440x900
B ON OFF ON ON 1600x1200
C ON ON OFF OFF 1680x1050
D ON ON OFF ON 1920x1080
E ON ON ON OFF 1920x1200
F ON ON ON ON N/A
EDID
Selection
60
Hz
50
123
4
ON
5
NOTE This setting is for
1024x768@60 Hz,
preset 2 (factory default)
COMPUTER IN
AUDIO
IN OUT
MONITOR OUT
IR OUT
S G
PVT RGB D Plus
G R L
RGB A
OUT
RGB B
OUT
G S
123
4
ON
5
EDID
Switch
PoleVault IP Systems • Installation — Stage 5 (Configuration)42