Extron electronic SVS 100 Switch User Manual


 
SVS 100 Installation
2-5
Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative
(-) terminal will damage the audio output circuits.
By default, the audio output follows the video switch. Audio breakaway,
commanded via the Windows-based control program or under
RS-232/RS-422 control, allows the user to select from any one of the four audio
input sources. See to chapter 5, Serial Communication, for details.
Genlock connections
A genlock device (black burst generator) can be connected to the SVS 100 via the
BNC connectors shown below. The genlock feature allows the SVS 100 to be
synchronized with other system components for seamless vertical interval
switching between sources. See Genlock and Vertical Interval Switching in this
chapter.
Figure 2-6 — Control device and external sync connections
10
Genlock In connector — Connect an external black burst signal to this BNC
connection for genlocking the video signal in broadcast or other sync-critical
applications.
11
Genlock Out connector — Connect any downstream equipment that
requires genlocking to this BNC connector to route the black burst signal
throughout the system in broadcast or other sync-critical applications.
RS-232/RS-422 connection
12
RS-232/RS-422 port — Connect a host device, such as a computer or touch
panel control, to the SVS 100 via this 9-pin D connector for serial
RS-232/RS-422 control. See chapter 5, Serial Communication, for details on
how to install and use the control software and the SIS commands.
The SVS 100 comes from the factory already configured for RS-232. To set the
SVS 100 for RS-422 operation, please see “Configuring the SVS 100 for
RS-422” in the Appendix.
Genlock and Vertical Interval Switching
For vertical interval switching (to allow clean switching between signals from
several devices during the vertical blanking period of each signal), a composite
sync signal can be applied at the Genlock In connector, and also passed to another
device via the Genlock Out connector.
OUTPUT
1LR
RS-232/422
REMOTE
GENLOCK
IN OUT
10
11
12