FortiSwitch-5003A CLI reference config
FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
01-30000-85717-20081205 97
Examples
This example shows how to enable the FortiSwitch-5003A board to listen for heartbeat packets on the
interfaces for chassis slots 6, 8, and 10:
config switch fabric-channel physical-port
edit "slot-6"
set heartbeat enable
next
edit "slot-8"
set heartbeat enable
next
edit "slot-10"
set heartbeat enable
end
This example shows how to bring down the slot-2/1 FortiSwitch-5003A interface. You may need to
bring this interface down to disable communication between fabric channel 1 and fabric channel 2.
config switch fabric-channel physical-port
edit slot-2/1
set status down
end
Related topics
• config switch fabric-channel interface
• config switch fabric-channel stp instance
• config switch fabric-channel stp settings
• config switch fabric-channel trunk