Hardware installation Resetting a FortiController-5103B board
FortiController-5103B Session-Aware Load Balancer Guide
10-500-161552-20140822 21
http://docs.fortinet.com/
9 Turn both handles to their fully-closed positions.
When the handles are fully-closed they lock into place.
10 Carefully slide the board completely out of the slot.
11 Re-attach the protective metal frame if you are going ship the FortiController-5103B
board or store it outside of a chassis.
Resetting a FortiController-5103B board
You can use the following procedure to reset a FortiController-5103B board without
removing it from the chassis.
To reset a FortiController-5103B without removing the board from the chassis
You do not have to loosen the retention screws or adjust the position of the
FortiController-5103B board to use this procedure.
To complete this procedure, you need:
• An ATCA chassis with a FortiController-5103B board installed
• An electrostatic discharge (ESD) preventive wrist strap with connection cord
1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on the chassis or frame.
2 Unlock the right handle by squeezing the handle lock.
3 Pivot the right handle open.
The handle can only pivot a short distance. Pivoting the right handle turns off the
microswitch which powers down the board, turning off all LEDs except the IPM LED
which turns on.
Fully Closed
and Locked
Alignment Pin
Handle
Close
Alignment Pin
Handle
FortiController-5103B boards must be protected from static discharge and physical
shock. Only handle or work with FortiController-5103B boards at a static-free
workstation. Always wear a grounded electrostatic discharge (ESD) preventive wrist
strap when handling FortiController-5103B boards.
Unlock
Handle