Fujitsu 600C Scanner User Manual


 
4-43
4.4.8 OBJECT POSITION command
The following table shows the normal sequence of the OBJECT POSITION command when used with this
scanner.
Table 4-20
Step Bus phase Initiator operation
←→
Target operation
I BUS FREE Verifies bus free
2 ARBITRATION Obtains bus-usage
right
3 SELECTION Selects target
Drives BSY signal
4 MESSAGE OUT Selects logical unit
5 COMMAND
Specifies OBJECT POSITION (CDB)
Loads/unloads paper (ADF)
6 STATUS Reports GOOD status
7 MESSAGE IN Reports message (Command Complete)
Release BSY signal
8 BUS FREE