7.2 Installation Specifications
fi-4120C2 Image Scanner Operator’s Guide 95
SCANNER SPECIFICATION
7
7.2 Installation Specifications
Item Specification
Dimensions (mm)
(Without ADF paper chute
and Stacker)
Depth Width Height
168 (6.6 in) 301 (11.8 in) 158 (6.2 in)
Installation Space (mm)
(D x W x H)
700 (27.6 in) x 400 (15.8 in) x 380 (15.0 in)
Weight (kg) 3.5 (7.7lb)
Input
power
Voltage 100 to 120 VAC ±10%
220 to 240 VAC ±10%
Phases Single-phase
Frequency 50 / 60 ± 3Hz
Power consumption 28 W or less
ATTENTION
Installation Space is the reference value of an installation space
required to read A4 manuscript.
Item Specification
Ambient
condition
Device
status
Operating Not operating
Temperature 5 to 35 °C
(41 to 95°F)
-20 to 60 °C
(-4 to 140°F)
Humidity 20 to 80 % 8 to 95 %
Heat capacity 24.1 kcal / H or less
Shipping Weight (kg) 5.0 (11.02 lb)