5.3 Remedying Common Troubles
fi-5530C Image Scanner Operator’s Guide 89
TROUBLESHOOTING
5
*) For details on how to clean dirty locations, refer to "3 DAILY CARE" on page 53.
Clean dirty locations. (*)
YES
Do not press down the ADF
or place heavy object on
the ADF during scanning.
NO
YES
Is the ADF cover pressed down or
heavy object placed on the ADF
during scanning?
YES
Do not allow anything to
cause the scanner to
vibrate while scanning.
Is something causing the scanner
to vibrate during scanning?
NO
NO
Symptom 6
Images are distorted or blurred.
YES
Is the scanner installed on a flat,
level surface?
Install the scanner on
a flat, level surface.
NO
Are the upper/lower glasses inside
the ADF clean?
If you cannot solve the problem
after taking measures, check the
items in "5.4 Items to check before
contacting the dealer where you
bought the scanner" and contact
the dealer or an authorized
FUJITSU service provider.