Sense Data and Error Recovery Methods
370 C141-C013
Table 6.4 Additional Sense Code and Additional Sense Code Qualifier (6/6)
C* Q*
Name Explanation
Sense
key
4E 00 Overlapped commands
attempted
Before execution of a tagged command was completed, the same
INIT issued a command to the same LUN with the same tag.
B
55 04 Insufficient Registration
Resource
PERSISTENT RESERVATION OUT command is issued from
insufficient device server resource.
5
5D nn SMART predictive failure SMART related sense data
•
12: The read error rate attribute has reached the failure
threshold.
•
14: The frequency of grown defect allocation attribute has
reached the failure threshold.
•
41: The write error rate attribute has reached the failure
threshold.
•
43: The seek error rate attribute has reached the failure
threshold.
•
56: The spin up time attribute has reached the failure
threshold.
•
64: The remaining alternate sector count attribute has
reached the failure threshold.
•
FF: The drive is in test mode.
0, 1, 6
C4 nn Drive Failure A serious error was detected in the drive's control system.
('nn' is a Fujitsu unique code)
•
00: Abnormal Rotation of Spindle Motor
•
01: Any error at Spindle Motor Start
•
30: On track failure
4