Fujitsu MBB2073RC Computer Drive User Manual


 
Sense Data and Error Recovery Methods
376 C141-C013
Table 6.5 Sense data error classification (2/3)
K* C* Q*
Outline of Error
L*
Recovery Method
(See Table 6.6.)
31 00 Medium form at corrupted Need 18
FORMAT command failed
The data format on the disk media is not correct.
3
31 01
The data format on the disk media is not correct.
Peripheral device write fault Need 7 4 03 xx
This is an error of the disk drive's write system.
32 01 Defect list update failure
These are errors detected in the operation of the disk
drive.
4 32 00 No defect spare location available None 19
No usable alternate blocks exist on the disk drive.
4 40 nn Diagnostic failure on component 'nn' Need 13
An error was detected in the HDD's self-diagnosis.
4 44 nn Internal target failure Need 20
An internal hardware error or a microcode detection
error was detected in the HDD.
4 4C xx Calibration failed Need 10
C4 xx Drive failure
The initial seek was terminated abnormally. Or, a
serious error was detected in the drive's control system.
5 20 00 Invalid command operation code None 2
21 00 Logical block address out of range
24 00 Invalid field in CDB
25 00 Logical unit not supported
26 00 Invalid field in parameter list
There is an error in the command specification contents.
* K: Sense Key C: Additional Sense Code
Q: Additional Sense Code Qualifier L: Logging Necessary? (shown in Section 6.2.3)