Fujitsu RX600 S5 Server User Manual


 
140 Operating Manual RX600 S5
Appendix: server specification
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-4892-003.fm
Dimensions / Weight
Dimensions (Base unit specific)
Environmental
Weight up to 46 kg
Weight notes Weight may vary depending on actual configuration
Rack mounting kit Rack mounting kit as option (standard for the
japanese market)
Rack (W x D x H) 482.6 mm (Bezel) / 445 mm (Body) x 770 x 176 mm
Mounting Depth Rack 728 mm
Height Unit Rack 4 U
19" rackmount Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Noise emission Measured according to ISO 7779 and declared
according to ISO9296
Sound pressure
(LpAm)
46 dB(A) (idle) / 51 dB(A) (operating)
Sound power (LWAd;
1B = 10dB)
6.2 B (idle) / 6.6 B (operating)
Noise notes /
description
at ambient temperature < 23°C
Operating ambient
temperature
10 - 35°C
Operating relative
humidity
10 - 85 % (non condensing)
Exhaust air volume Ambient temp. m
3
/h m
3
/min
<25°C 49 0.82
30°C 87 1.45
35°C 126 2.1