Fujitsu RX600 S5 Server User Manual


 
46 Operating Manual RX600 S5
Rack installation/removal of server Hardware installation
© cognitas. Gesellschft für Technik-Dokumentation mbH 2010 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-4887-003.fm
You must ensure that the safety mechanisms on the server, e.g. stoppers or
retaining systems, are functioning correctly.
The shape of the rack support uprights must ensure that the support
systems can be bolted to the front.
The support systems have a linear alignment feature to ensure that they can
be adjusted to different rack depths.
No cable management support (delivered with the mounting kit).
Climatic conditions:
An unobstructed air intake in the rack front and air discharge in the rear
cover of the rack are essential for ventilation of the installed server.
In general, the ventilation concept ensures that the necessary cooling is
achieved by the horizontal self-ventilation of the installed devices (air flow
from the front to the rear).
Power supply:
For installation in 3rd party racks, you must ensure that the appropriate
socket strips are present.
4.2.2 Installation in PRIMECENTER/DataCenter rack
For installation in a PRIMECENTER/DataCenter rack, the following parts are
required:
Support bracket
One support system on the left and one on the right
M5 centering fixtures (screws with integrated plugwashers)
I The descriptions and figures in this section refer to the current
support system. For other support systems you will find the
appropriate description in the packaging of the rack mounting kit.
For information on mounting of the rails in the 19-inch standard rack
(for the Japanese market) please refer to the "Rack mount guide".
General information regarding server installation in the rack is
included in the technical manual for the appropriate rack.
For information on mounting of the server in the 19-inch standard rack
(for the Japanese market) please refer to the Rack mount guide.