Fujitsu RX600 S5 Server User Manual


 
RX600 S5 Operating Manual 141
Appendix: server specification
Electrical values
Power supply
configuration
Up to 4 hot-plug power supplies
Base unit equipped with 2 power supplies;
redundancy as option
Max. output of single
power supply
850 W
Hot-plug power supply
redundancy
Ye s
Rated voltage range 100 - 127 V / 200 - 240 V
Rated frequency range 50 - 60 Hz
Active power min.
(typical config)
750 W
Active power max.
(typical config)
1950 W
Rated active power max. 3360 W (14 A x 240 V)
Apparent power max.
(per system unit)
1990 VA
Heat emmission 7020.0 kJ/h = 6653.7 BTU/h