1.5 Technical data
Electrical data (hot-plug power supply unit)
Text in italics indicates commands or menu items.
"Quotation marks" indicate names of chapters and terms that are being
emphasized.
Ê describes activities that must be performed in the order
shown.
V CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
I indicates additional information, notes and tips.
Rated voltage range 100 - 127 V / 200 - 240 V
Frequency 50 Hz - 60 Hz
Rated current (basic configuration) 3.1 A (240 V)
Max. rated current 14 A (240 V)
Active power min. (typical configuration) 750 W
Active power max. (typical configuration) 1950 W
Rated active power max. 3360 W (14 A x 240 V)
Apparent power (typical configuration) 1990 VA
Heat dissipation 750 W/h = 2559 btu/h
1950 W/h = 6654 btu/h
3360 W/h = 11465 btu/h
Main power fuse 16 A
Protection class I