offered by Busse-Yachtshop.com
4. NAVTEX OPERATION: NAVNET
4-2
4.2 Setting Up Navtex Stations, Messages, Alarms
You may freely select the navtex stations from which to receive and the
messages categories to receive. Further, you may enable or disable received
message alarms.
1. At the standby display, press the NAVTEX soft key. If you have received
some navtex messages, their data are shown as below.
NAVTEX
SELECT
MSG
RETURN
RX
SETUP
▲
1. IA55 JUN/06 03:57 518kHz
2. IA53 JUN/06 03:58 518kHz
3. IA52 JUN/06 03:59 518kHz
4. IA48 JUN/06 04:01 518kHz
RCV
NAVTEX
Appears when the mode is
NAVTEX or FAX(TIMER)&NAVTEX
Navtex message data display
2. Press the RX SETUP soft key.
RX
SETUP
EDIT
RETURN
▲
FREQUENCY 518 kHz
STA. SELECTION MODE MANUAL
STATION SELECTION .
MESSAGE SELECTION
MAX ERROR RATE 33%
ALARM (SAR MSG) OFF
ALARM (WARNING MSG) OFF
RX setup menu
3. FREQUENCY is selected, press the EDIT soft key.
FREQUENCY
▲
▼
490 kHz
518 kHz
Navtex frequency options
4. Rotate the [ENTER] knob to choose 490 kHz or 518 kHz depending on the
station and press the ENTER soft key.