Gateway E-9722R Computer Hardware User Manual


 
CHAPTER 4: Installing Components
40
5 Lift one side of the fan cage (2) and disengage the retention tab (3), then disconnect the
fan power and fan tach cables from the system board and remove the fan cage from the
chassis.
6 Insert the fans into the new fan cage.
7 Connect the fan power and fan tach cables to the system board, then insert the retention
tab (1) into the corresponding clip on the chassis and push the other side of the fan cage
down (2), making sure that the retaining clip is inserted into the hole in the chassis.
8 Replace the fan duct by placing it into the chassis.
9 Follow the instructions in “Closing the server case” on page 27.
Important
Make sure that the arrows on top of the fans indicating airflow point to the
back of the chassis.