GBC 4064WF-1 Operation Manual
© 2009 GBC an ACCO Brands Co. Page 11
LCD QUICK REFERENCE SHEET
TOP:265*F
BOT:032*F
POS:LAM
FRONT TENSION ERR!!!!
WAIT
SPD: 03ft
FRONT
Figure 1
TOP:265*F
BOT:032*F
POS:LAM
FRONT TENSION SEARCHING!
WAIT
SPD: 03ft
FRONT
Figure 2
TOP:265*F
BOT:032*F
POS:LAM
REAR TENSION ERR!!!!
WAIT
SPD: 03ft
FRONT
Figure 3
TOP:265*F
BOT:032*F
POS:LAM
REAR TENSION SEARCHING!
WAIT
SPD: 03ft
FRONT
Figure 4
TOP:265*F
BOT:032*F
POS:LAM
E-SWITCH PRESSED!!!
WAIT
SPD: 03ft
FRONT
Figure 5
TOP:265*F
BOT:032*F
POS:LAM
FR ACTIVATE SAFETY!!!
WAIT
SPD: 03ft
FRONT
Figure 6
FIGURE 1:
When jobs are changed, the shim dials will
automatically rotate to the desired setting. Front
Tension Error indicates that the Front Shim Dial
has not located the desired setting.
• Make sure Air is applied to the machine.
• Re-set the Main Power.
FIGURE 2:
When jobs are changed, the shim dials will
automatically rotate to the desired setting. As the
Front Shim Dials are locating the desired setting,
the LCD will indicate this by displaying: FRONT
TENSION SEARCHING.
• Wait for Shim Dial to locate the desired
setting.
FIGURE 3:
When jobs are changed, the shim dials will
automatically rotate to the desired setting. Rear
Tension Error indicates that the Rear Shim Dial
has not located the desired setting.
• Make sure Air is applied to the machine.
• Re-set the Main Power.
FIGURE 4:
When jobs are changed, the shim dials will
automatically rotate to the desired setting. As the
Rear Shim Dials are locating the desired setting,
the LCD will indicate this by displaying: REAR
TENSION SEARCHING.
• Wait for Shim Dial to locate the desired
setting.
FIGURE 5:
When an Emergency Stop is pressed, the LCD will
indicate: E-SWITCH PRESSED!!
• Locate the Emergency Stop that is
activated.
• Return the Emergency Switch to normal
position.
• Now the Machine can be operated.
FIGURE 6:
When a Safety Interlock is not correctly
positioned, the LCD will read: ACTIVATE
SAFETY!
• Locate the Safety Interlock that is not
properly set.
• Now the Machine can be operated.