GE MDS Intrepid-HC HP Installation Guide B-1
Appendix B: PPP/SLIP Driver Installation
Installation for Windows 2000/2003/XP
1. Click Start, Settings, Network and Dialup, Make New Connection.
2. Click Next.
3. Mark Connect directly to another computer.
4. Click Next.
5. Mark Guest.
6. Click Next.
7. Select Communication cable between two computers.
8. Click Next.
9. Select For all users.
10. Click Next.
11. Type The connection Name.
12. Click Finish.
Configuring PPP
1. Click Start, Settings, Network and Dialup.
2. Select The connection Name.
3. In the General tab click Configure, and set the speed to 38400.
4. Check Enable Hardware flow control.
5. Uncheck Modem Error control, Modem Compression.
6. Select Network tab.
7. Select Type PPP.
8. Select Internet protocol (TCP/IP) and click Properties.
9. Uncheck all options except TCP/IP.
10. Check Use the following IP.
11. Insert IP Address (the same subnet as the Indoor Unit).
12. Click OK.
13. Click OK.