SW3 switches 1 to 8
The switch positions on SW3 are for selecting the Ethernet device
type.
These switches are reserved for technical support. Do not use.
SW4 switches 7 and 8
Switches 7 and 8 on switch 4 control the communication protocol
between the PBe at port 1 and the DVR or PC. Normally this is
set at RS-232.
Table 5. SW3 switches 1 to 8 - Device type
SW3
Switch function 1 2 3 4 5 6 7 8
Ethernet Analyzer UUUUUUUU
Generic UUUUUUUD
Native ATM UUUUUUDU
Verifone POS UUUUUUDD
Table 6. SW4 switches 7 and 8 - communication protocol
SW4
Communication protocol 7 8
RS-232 D U