Hand Held Products 3700 CCD Barcode Reader User Manual


 
Set–Up and Installation 3–3
3.3.2 Set–up Procedure
This procedure will verify that bar code scanning and communications between the host
and the 3700 has been established.
To setup serial communications to the scanner
1) Connect the RS–232 communications (I/O) cable between the 3700 and the PC
serial port. (You may require a 25 pin to 9 pin converter and Null Modem adapter.
Contact your Hand Held Products sales representative or distributor for assistance.)
2) Connect power to the 3700. The scanner should beep once.
3) Start serial communications software program, such as PCTools Desktop (Central
Point Software), on the PC.
4) On the PC, set up the serial communications program to match the 3700 default
values:
Baud rate = 9600
Parity = Even
Stop Bits = One
Data Bits = Seven
5) The default factory scanner configuration for the SCANTEAM 3700 requires a
serial command from a host to trigger a scan. Change the trigger mode to
“Continuous Read, Send Once, Clear on Timeout” by typing <Kg , 1>. The elapsed
time between the typing of each character should not exceed 5 seconds. The
illumination LEDs should light in response to the command.
6) Confirm communications to the 3700 with the test label below. Observe that the
LED reflector is illuminated. Scan the test label“ABC123” below. The default
scanner configuration for preamble is Port ID and Code ID. Default postamble is
CR (carriage return) and LF (line feed). Observe within 3 seconds the message
“1bABC123” on the PC.
“1” = Port ID
“b ” = Code ID (Code 39 code ID is “b”)
“ABC123” = The bar code label
A B C 1 2 3
This completes set–up of the SCANTEAM 3700 Machine Mount CCD for evaluation.
You are now ready to configure the 3700 to explore the functions and features.
Instructions for configuring the 3700 using configuration and operational commands are
provided in Chapter 4, Configuring the SCANTEAM 3700.