HP (Hewlett-Packard) 5187-2725 Server User Manual


 
Known Problems and Troubleshooting
Known Install/Update Problems
Appendix B148
How Do You Know
If This Affects You
If you update your system to HP-UX 11i v2 from either HP-UX 11i v1.6
or HP-UX 11i v2, you will encounter this error message.
The problem is caused by an ‘orphaned’ fileset IDS-AGT-KRN left on your
system in order to prevent an unnecessary reboot, and results in
swverify errors after the update.
What to Do You can safely ignore this message. HIDS will work properly. However,
if you want to ensure a clean installation of IDS:
1. Save any customization files to a safe location
2. Use the swremove command to remove HIDS (J5083AA)
3. Use the swinstall command to install HIDS (J5083AA) from the
HP-UX 11i v2 media.
“Incorrect protocol version (20) in volboot file” Error
After updating to HP-UX 11i v2 from HP-UX 11i v1.6, the following error
message may appear during reboot:
Starting vxconfigd in boot mode (pre_init_rc).
vxvm:vxconfigd: WARNING: volboot: Incorrect protocol version (20)
in volboot file.
vxvm:vxconfigd: WARNING: volboot: Using the highest supported
protocol version 40
Checking root file system.
How Do You Know
If This Affects You
You will encounter this error if you updated an HP-UX 11i v1.6 system
with VxVM 3.1 as your volume manager to HP-UX 11i v2 with VxVM
3.5. The problem is caused by different version values in the volboot file
(20 in VxVM 3.1; 40 in VxVM 3.5
What to Do You can safely ignore this error message.
“Unable to flush file system metadata for /stand to
disk” Warning
The following warning message will appear just before your system
reboots after updating to HP-UX 11i v2 from HP-UX 11i v1.6:
WARNING: Unable to flush file system metadata for /stand to
disk