HP (Hewlett-Packard) 540 Printer User Manual


 
Environmental Specifications
Environmental Specifications
Category Specification
Temperature
Operating
Non-Operating
Recommended Operating
5 to 40 C (41 to 104 F)
-40 to 60 C (-40 to 140 F)
15 to 35 C (59 to 95 F)
Relative Humidity 10% to 80% RH at 30 C
Altitude
Operating
Non-Operating
0 to 3048 meters (10,000 feet)
0 to 4572 meters (15,000 feet)
Mechanical Vibration
Frequency Range
Operating (Random)
Non-Operating (Random)
Swept Sine
5 to 500 Hz
Approximately 0.21 G rms
Approximately 2.09 G rms
0.5 G (0 to peak)
BTU Output 41 BTU/hour (maximum)
ESD per CISPR24 Part 2 Passed
1
, No Waivers
Noise Levels per ISO 9296
Sound Pressure (L
pAm
)
EconoFast Mode
Presentation Mode
Sound Power (L
wAd
)
EconoFast Mode
Presentation Mode
49 dB(A)
46 dB(A)
6.4 B(A)
6.1 B(A)
1. ESD contact points include the carriage rod, paper guide, service station motor, interface
port, and pivot return spring. Air discharge points include the carriage assembly, rear seams,
and top seams.