HP (Hewlett-Packard) 686713-S01 Server User Manual


 
Component identification 15
Systems Insight Display
LED and color
Health LED
System power
LED
Status
Power supply (amber)
Amber Green
Redundant power supply is installed and
only one power supply is functional.
AC power cord is not plugged into
redundant power supply.
Redundant power supply fault
Power supply mismatch at POST or
through hot-plug addition.
Power cap (off)
Amber Standby
Power cap (green)
Flashing green Waiting for power
Power cap (flashing
amber)
Amber Power cap has been exceeded
Power cap (green)
Green Power is available
IMPORTANT:
If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
SAS and SATA device numbers
With optional drive cages installed, the server supports up to 24 SFF drives or up to 18 LFF drives. The server
does not support mixing SFF and LFF drives.
HP recommends that you populate drive bays starting with the lowest SAS or SATA device number. Drives
are numbered from left to right in each component box. Component boxes are numbered 1 through 3, from
bottom to top.
SFF drives