HP (Hewlett-Packard) 686713-S01 Server User Manual


 
Hardware options installation 51
CAUTION: To avoid damage to the hard drives, memory, and other system components, the air
baffle, drive blanks, and access panel must be installed when the server is powered up.
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 20).
o For rack models, if installed, remove the security bezel (on page 22).
2. Power down the server (on page 20).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o For tower models, place the server on a flat, level surface with the access panel facing up.
o For rack models, extend the server from the rack (on page 25).
5. Remove the access panel (on page 24).
6. Remove the air baffle (on page 25).
7. Open the DIMM slot latches.
8. Install the DIMM.
If you are installing DIMMs in lock-step configuration, configure this mode in RBSU ("HP ROM-Based Setup
Utility" on page 91).
For more information about LEDs and troubleshooting failed DIMMs, see Systems Insight Display LED
combinations (on page 14).
Optical drive cage option
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 20).
o For rack models, if installed, remove the security bezel (on page 22).
2. Power down the server (on page 20).