3 Library Operation
This section includes:
Automated Mode
Automated mode is the normal operating mode of the tape library. The controlling
software instructs the hand assembly to move cartridges among the storage slots, tape
drives, and cartridge access port (CAP) without operator intervention.
Opening the Front Door (With Power)
To open the front door when tape library power exists:
1. Press the Open Door button on the keypad.
a. The software allows the current job to complete.
b. The software retracts the robot into the robotic unit to prevent the robot from
being damaged and to prepare it for servicing.
2. When the Open Door indicator turns on, use the key to open the door.
Securing the Front Door (With Power)
To secure the front door when tape library power exists, push it closed and use the key
to lock it.
Entering a Cartridge Through the CAP
The base module CAP contains a standard five slot magazine. The expansion module
CAP has two five slot magazines. The CAPs allow you to insert cartridges and remove
cartridges from the tape library.
To enter a cartridge into the CAP:
1. Be sure that the CAP Prevent/Allow state is set to Allow.
2. Press the CAP Open button on the keypad.
The robot opens the CAP door and the CAP Open LED is turned on.
3. Grip the handle of the magazine and slide it out of the CAP and onto the door.
Automated Mode
3-1
Manual Mode 3-4
Note. Do not remove the magazine from the door. Leaving the magazine on the door rails
will allow the magazine to slide easier into the CAP.