Hitachi MP-96RD625-01 Computer Drive User Manual


 
Chapter 5 Configuring Storage Systems and Logical Paths 5-11
Hitachi Universal Replicator for IBM /OS User’s Guide
The path group ID is within the range of 1-FF (hexadecimal). Up to 64
path group IDs can be registered per storage system.
Note: In the current version, the path group IDs always take the
default values and cannot be changed.
8. In the Add DKC window, select a primary storage system port and a
remote storage system port to configure a logical path.
9. Select Option.
10. In the DKC Option window, configure logical path options and storage
system options.
For detailed information about the options, see the next section and read
explanations below
Figure 5-4.
11. Select Set to close the DKC Option window.
12. See the Preview list to check the settings that you have made.
If you want to modify a setting, select and right-click the setting from
the Preview list and then select Modify. A window appears and allows
you to modify the setting.
If you want to cancel a setting, select and right-click the setting in the
Preview list and then select Cancel.
13. Select Apply to apply the settings that you have made.
Note: If an error occurs, the rightmost column of the Preview list displays
the error code. To view detailed information about the error, right-click the
error code and then select Error Detail. An error message appears and
gives you detailed information about the error.