Honeywell 3800i Scanner User Manual


 
3 - 8
Aimer Beam Time-Out (Aimer Beam option only)
Aimer Beam Time-Out powers down the aimer beam after a time-out if the trig-
ger is still pulled and there isn’t a valid decode. Scan the bar code below, then
set the time-out by scanning digits (from 0 - 240,000 ms) from the
Programming Chart inside the back cover of this manual and then scan Save.
Default = 0 (no time-out)
Centering Window
Use the centering feature to narrow the scanner’s field of view so the scanner
reads only the bar code you want. When centering is turned on, the scanner
only reads codes that intersect or are contained within the centering window
you set up. At least part of a bar code must be within the window to be decoded
or output by the scanner.
To change the left or right edge of the centering window, scan Centering On,
then scan one of the following bar codes. Then scan the percent you want to
shift the centering window using digits on the inside back cover of this manual.
Scan Save. Default Centering = 40% for Left, 60% for Right.
Time-Out Duration
Left of Centering Window
Right of Centering Window
* Centering Off
Centering On