Honeywell 3800i Scanner User Manual


 
7 - 4
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
scanner looks for a Codabar symbol having a “D” start character, adjacent to a
symbol having a “D” stop character. In this case the two messages are concat
-
enated into one with the “D” characters omitted.
Select Require to prevent the scanner from decoding a single “D” Codabar sym-
bol without its companion. This selection has no effect on Codabar symbols
without Stop/Start D characters.
Codabar Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
A12D D34A
Codabar
Character
Stop Start StopStart
On
* Off
Require
Minimum Message Length
Maximum Message Length