6 - 4
Laser Emulation Polarity
The Polarity can be sent as standard with white bars high, or reversed with
black bars high.
Default = White High.
Laser Emulation Idle
The idle describes the state of the scanner when no data is being transmitted.
When in Non Decoded mode, you must set the scanner’s idle state to match the
idle state for the device to which the scanner is connected.
Default = Idle High.
Secondary Trigger Mode
Manual Trigger:
You must press the scanner trigger to scan. When not scan-
ning, idle power is maintained.
Default = Manual Trigger
.
Automatic Trigger:
The scanner scans continuously at full power.
Presentation Mode:
The LEDs are off until a bar code is presented to the
scanner. Then the LEDs turn on automatically to read the code. Presentation
Mode uses ambient light to detect the bar codes.
* White High
Black High
Idle Low
* Idle High
* Manual Trigger
Automatic Trigger
Presentation Mode