Honeywell 3800i Scanner User Manual


 
7 - 3
Codabar Start / Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit
.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can pro-
gram the scanner to read only Codabar bar codes with Modulo 16 check char-
acters.
Default = No Check Character.
No Check Character
indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to
Validate and Transmit
, the scanner will only
read Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.
When Check Character is set to
Validate, but Don’t Transmit
, the unit will only
read Codabar bar codes printed
with
a check character, but will not transmit the
check character with the scanned data.
Transmit
* Don’t Transmit
* No Check Character
Validate Modulo 16 and Transmit
Validate Modulo 16, but
Don’t Transmit