Honeywell 3800i Scanner User Manual


 
3 - 11
Other Programming Selections
Discard
This exits without saving any Output Sequence changes.
Output Sequence Editor
Require Output Sequence
When an output sequence is
Required
, all output data must conform to an
edited sequence or the scanner will not transmit the output data to the host
device. When it’s
On/Not Required
, the scanner will attempt to get the output
data to conform to an edited sequence, but if it cannot, the scanner transmits all
output data to the host device as is.
When the output sequence is
Off
, the bar code data is output to the host as the
scanner decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Enter Sequence
Default Sequence
Required
On/Not Required
* Off