Honeywell 7600 Scanner User Manual


 
18
Figure 20: RS232/RS485, Interface
RS485
1. Turn off the host system.
2. Connect the MVC cable to the
1
st
jack down from the top of
the 7600.
3. Connect the other end of the
MVC cable to the host.
Before continuing verify that the
MVC cable is connected to the
appropriate interface jack on the
scanner. An incorrect cable
connection can cause
communication problems or
potential damage to the scanner.
Manufacturers Note:
Plugging the scanner into the
serial port of the PC does not
guarantee that scanned
information will appear at the PC.
A software driver and correct
configuration setting are also
required for proper
communication to occur.
4. Turn on the host system.
5. Scan the Load 46xx IBM Defaults
bar code to configure the 7600
for RS485 communication.
For additional communication options for RS485 interfaces refer to the
MetroSelect Programming Guide (
PN 00-02407).
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must meet the
requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power
source should meet applicable performance requirements for a limited power source.
Recall Defaults
Load 46xx IBM Defaults
³ 9 9 9 9 9 5