Honeywell 7600 Scanner User Manual


 
46
Scanner and Cable Terminations
Scanner Pinout Connections
The 7600 scanner interfaces terminate to 10-pin modular jacks located on the
back of the unit. The serial # label indicates the model number of the scanner.
Figure 32: Scanner Interface Ports
MS762x-13 OCIA MS762x-13 RS485
Pin Function Pin Function
1
Ground
1
Ground
2 NC 2 RS-232 Transmit Output
3 NC 3 RS-232 Receive Input
4 RDATA
4 RTS Output
5
RDATA Return
5
CTS Input
6 Clock in
6 DTR
7
Clock out
7
IBM B- (D-)
8
Clock in Return/
Clock out Rtrn
8 IBM A+ (D+)
9 +5VDC 9 +5V IN
10 Shield Ground 10 NC
MS762x-13/-37 Auxilary Port RS232 IN Only
Pin
Function
1
Ground
2
RS-232 Receive Input
3
RS-232 Transmit Output
4
RTS In
5
CTS Out
6-10
NC
Continued on next page